Railways
Industrial
Shop
- Control panel A, C&D Applicable for Operations & Controlling function of 3-Ph locomotive.
- Equipped with all necessary protection device for locomotive auxiliary equipment
- Provide interface between control electronics and other devices
- Equipped with switchgear for various locomotive functions.
- Marking of each wire for identification
- Wide Band Contactors are used. Compatible with Head on Generation rolling stock.
- 32-bit Arm Cortex controller-based CPU and IO operation.
- RS485 port for Display and standalone controller interface.
- 18.5” TFT Touch Screen is used for control and monitoring.
- 750 VAC, 3 Phase, 4/3Wire System, 50 Hz
- Monitoring of coach data from centralized remote location via GPS
- Hard copy printing of Alarm / Trip summary on Mini printer
- 32-bit controller based CPU and I/O operation
- 18.5” TFT Touch Screen Display for control and monitoring
- RS-485 port for Display and standalone controller interface
- Input sense Voltage: 240 VAC ±10%, 50-60Hz
- Adjustment of input values: Setting Range available from 0 to 240 V, Where Un = 200V
- Auxiliary Supply: Nominal : 48 VDC Operating range (36 V to 68 VDC)
- Supply Rated Burden: Supply Rated burden 3W
- Maximum Value of Harmonics on Input: Less than 5%
- A low voltage high current DC power supply with oil cooled regulator and oil cooled transformer.
- 3 phase 415V AC fed into motorized or hand operated oil cooled dimmer regulator. Regulated output again connected to oil cooled step down transformer with oil immersed diode rectifier.
- Close loop controller with current raise or lower command
- Protection and annunciation circuit
- DC Voltage: 0 to 20VDC
- Input : 415V±10%
- DC Output: 80V
- DC Current: Upto 10 kA
- l Current Control Range : 20-100%
- Rating Class ‘B’ of IS 4540
- Input Voltage: 3 phase, 4 wire, 415 V ±10%
- Frequency: 50 – 60 Hz
- Output Voltage: 0-12 V (CV Mode)
- Output Current: 0-500A (CC Mode)
- T ambient: 50°C Max
- Wide Band Contactors are used. Compatible with Head on Generation rolling stock.
- 750 VAC, 3 Phase, 4/3Wire System, 50 Hz
- 110 VDC
- 415 VAC, 3 Phase, 4 Wire system, 50 Hz
- 190 VAC, 3 Phase, 4 Wire System, 50 Hz
- Wide Band Contactors are used.
- Compatible with HOG rolling stock.
- 750 VAC, 3 Phase, 4/3Wire System, 50 Hz
- 110 VDC
- 415 VAC, 3 Phase, 4 Wire system, 50 Hz
- Wide Band Contactors are used.
- Compatible with Head on Generation rolling stock.
- Enclosure protection: IP 65 (Underslung part of SBC)
- 750 VAC, 3 Phase, 4 Wire System, 50 Hz
- 415 VAC, 3 Phase, 4 Wire System, 50 Hz
- DC Current: upto 20 kA
- DC Voltage: upto 1000 VDC
- 6 / 12 / 24 pulse configuration
- Current / Voltage Stability : < ±1%
- Standards: IS / IEC