- Nominal Voltage: 830 VAC, 1 Phase
- Frequency: 50 Hz
- Power: 2 x 130 kVA at 0.8 PF
- AC output: 3 x 415 VAC, 50 Hz, Sine wave, VVVF
- DC Output: 2.2 kW, 110 VDC, 20 A
Railways
Industrial
Railways
- Nominal Voltage: 960 VAC,
- Frequency: 50 Hz
- Input Power Factor: Close to Unity at full Load
- Power: 500 kVA at power factor ≥ 0.8
- Nominal Voltage: 3 x 750 VAC, Sine Wave
- Input Voltage : 90 VDC to 170 VDC
- Output Current: 35 AAC
- Output Voltage: 415 VAC, 3 Phase, 50 Hz
- Power: 25 kVA at 0.8 pf
- Cooling: Natural Cooled
- Wide input Voltage Operating Range from 65 V to 165 VDC.
- High Resolution 10.4” 1024 x 768 High Resolution Display with 16.7M color for best clarity
- User adjustable LED backlight brightness and contrast settings with dedicated function keys.
- Spare keys provided for customer definable functions.
- Modular keyboard design for easy and intuitive navigation of various display screens.
- The HIRECT EoT unit is placed in a rugged enclosure with adjustable mounting bracket. The end-of-train devices (EOTs) provides information about brake pipe pressure measured at the rear of the train, and various status conditions.
- The EOT also processes and responds to HOT Instruction, for example emergency brake commands, train passages acknowledgement command.
- The air supply from the BP will be given to the EoT unit. The air Generator inside EoT unit will convert the pneumatic energy into DC supply, which will power the unit.
- EoT unit reports its current location to the HoT unit in regular interval. The radio unit used in both HoT and EoT are designed as per AAR S9152 V2.1 standard
- Equipped with Air turbine Generator and Battery
- Hirect EoTT system offers two HoT units for both cabs and both units will work in master-slave mode.
- HoT Units are intended to be fitted in both cabs of the locomotive with the display units for proper monitoring by the LP and ALP. Locomotive number shall be the unique identifier for the HoT device
- HoT Units are intended to be fitted in both cabs of the locomotive with the display units for proper monitoring by the LP and ALP. Locomotive number shall be the unique identifier for the HoT device
- Data storage facility with more than 30 days in FIFO basis is provided.
- Modular Design
- Connection: 3 Phase Bridge,
- Input Voltage: 698 VAC
- Output Current: 1860 ADC
- Output Voltage: 940 VDC
- Power: 1000 kVA
- Nominal Voltage: 760V / 830V AC at 22.5 kV, Single Phase,
- Frequency: 50 Hz
- Output Power: 180kVA continuous
- Output Voltage: 415V AC, ± 5 %, 3 Phase
- Output Current: 250 Amp. continuous / 600 Amp. for 5 seconds
- Parameters Rated Point Maximum Point
- Power 850kW 850kW
- Stator Frequency 65 Hz 132Hz
- Motor Voltage (phase to phase) 2180V 2180V
- Stator Current 270A 393A
- Nominal Voltage: 1000 VAC, 1 Phase
- Frequency: 50 Hz
- Power: 130 kVA at power factor ≥ 0.8
- AC output: 3 x 415 VAC, 50 Hz, Sine wave, VVVF
- Communication Bus: CAN/Ethernet/MVB
- Nominal Voltage: 350 VAC to 480 VAC for RBC and 190 VAC to 280 VAC for EBC
- Minimum Working Voltage: 350 VAC
- Working Frequency: 50 Hz ± 3%
- Power for RBC: 4.5kW
- Output Voltage: 110V – 135VDC (Selectable through user friendly keypad)
- Nominal Input Voltage: 890 V AC, Three Phase
- Input Frequency: 50 Hz
- Output Voltage: 1200VDC
- Output Current: 3800 A
- Size (WxDxH): 853mm X 1037mm X 1450mm