- Rating: 4.0 kW to 70 kW
- Output Current type I: 6.6 A
- Output Current type II: 20.0 A
- Input Voltage: For 7.5 kW and below : 240 V ±10% For 10.00 kW and below: 415 V ±10%
- No. of Brightness: 5 Step
Railways
Industrial
Shop
- Industance upto 30 mH
- DC Current upto 1000 Amps
- Aluminium Wound, Air Natural
- Class F Insulation
- IP 22 Protection
- Natural Air Cooled Rectifier
- 6 / 12 Pulse
- 3MW DC Substation Rectifier Supplied to
- Western & Central Railways
- 2MW DC Substation Rectifier Supplied for Kolkata Metro, Kolkata Transways & Mumbai Monorail
- Input Voltage: 415 Volts AC
- Phase: Single / Three
- Voltage Variation:±10%
- Frequency: 50 Hz
- Output Voltage: Single / Three ,30 kV – 200 kV DC Peak Mid Frequency ,30 kV – 120 kV DC Peak
- FDU is used in SB-2 Panel of 3-Phase AC Locomotives. This Fire detection Unit is used to sense any smoke present in the Locomotive during its operation and notify the driver about the same.
- FDU indicates the driver about any fault such as rupture, blockage, and leakage in its air suction system Via the LED Indicator display.
- The air is captured by suction system which is present in the locomotive. During its normal operation, if smoke is present in the Locomotive, the FDU will sense the smoke and generate the signal and send it to VCU. This message will be transmitted to DDU. DDU will display the fault “Fire Detection” at Subsystem 15, along with title “FIRE IN MACHINE ROOM”
- The Fire Detection Unit (FDU), which is installed in a metal case, consists of the following materials:
- Smoke detection unit, 2 smoke detectors are installed inside the case
- Visual indications for operations, fault/malfunction monitoring with alarm
- Wide Band Contactors are used. Compatible with Head on Generation rolling stock.
- Compact in Size and stainless steel is used for structure.
- 750 VAC, 3 Phase, 3Wire System, 50 Hz
- 110 VDC
-
- 750VAC, 3 Phase, 3Wire system, 50 Hz
- Wide Band Contactors are used. Compatible with End on Generation rolling stock.
- 750 VAC, 3 Phase, 4/3Wire System, 50 Hz
- 110 VDC
-
- 415 VAC, 3 Phase, 4 Wire System, 50 Hz
- 240 VAC, 1 Phase, 50 Hz
- Wide Band Contactors are used. Compatible with Head on Generation rolling stock.
- Compact in Size and stainless steel is used for structure.
- 750 VAC, 3 Phase, 4/3Wire System, 50 Hz
- 110 VDC
- 415 VAC, 3 Phase, 4 Wire system, 50 Hz
- Wide Band Contactors are used. Compatible with Head on Generation rolling stock.
- Compact in Size and stainless steel is used for structure.
- 750 VAC, 3 Phase, 4/3Wire System, 50 Hz
- 110 VDC
-
- 415 VAC, 3 Phase, 4 Wire system, 50 Hz
- Wide Band Contactors are used. Compatible with Head on Generation rolling stock
- Enclosure protection: IP 65
- 750 VAC, 3 Phase, 4/3Wire System, 50 Hz
- 110 VDC
- 415 VAC, 3 Phase, 4 Wire System, 50 Hz
- Operating AC Voltage: 11 kV, 22 kV&33 kV, ±10%, 3 phase, 50/60 Hz
- DC output Voltage: 50 V to 1000 V
- DC current: 1 kA to 70 kA
- No. of Pulse: 6 or 12
- Type of control: Thyristor with OCTC and/or OLTC
- I/P Voltage: 415 VAC, 3 phase, 50 Hz
- I/P Power: 13.5 kW
- Cooling Capacity: 7 Tonne
- Refrigerant Used: R 407 c
- Stainless Steel Structure for long durability