  • 6531 kVA without hotel load winding WAG9 Locomotive & designated as LOT 6500
  • 7775kVA with hotel load winding for WAP5 & WAP7 Locomotive & designated as LOT 7775
  • 9198 KVA Traction Transformer for 9000HP Locomotive with Aluminum / Steel Tank
  • Loco transformer is a front-end component with steps down 25kV AACl in ecentenary voltage to 1269 V for feeding to 3 phase regenerative drive which ultimately drives 3 phase asynchronous traction motors
  • The transformer is forced oil cooled with 2 circuits
  • Based on the IEC – 61375 TCN open standard which allows compatibility with 3rd party systems running same standard.
  • Input Operating Voltage Range: 65 to 165 VDC.
  • Four Digital I/O Cards per unit with each card having 16 Digital Inputs and 16 Digital Contact free outputs.
  • ll inputs channels are redundant internally for better reliability of the system.
  • One Analog I/O card with 8 Analog input channels and 8 Analog output Channels (User Configurable)